{"title":"Notifier Fire Alarm System","description":"\u003cp\u003eBrowse Notifier fire alarm devices and components, including smoke, heat, carbon monoxide, and multi-criteria detectors, manual alarm stations, monitor and relay modules, and loop controllers. Related items include end-of-line resistors and transmitter and zone relay modules for specific equipment.\u003c\/p\u003e\n\u003cp\u003eSelect devices by exact part number and the control panel’s documented compatibility requirements. Verify detector bases, communication protocol, electrical ratings, and any firmware or revision requirements in the manufacturer’s documentation. A shared brand name does not establish compatibility between different product generations or system families.\u003c\/p\u003e\n\u003cp\u003eCheck individual product specifications and package contents before ordering replacements or planning an expansion. Confirm the intended application and follow the manufacturer’s installation, programming, and testing instructions rather than assuming every device offers the same detection features, networking, or notification functions.\u003c\/p\u003e","products":[{"product_id":"notifier-fpc-951-addressable-multi-criteria-photo-and-carbon-monoxide-detector","title":"Notifier FPC-951 Addressable Multi-Criteria Photo and Carbon Monoxide Detector","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier FPC-951 Addressable Multi-Criteria Photo and Carbon Monoxide Detector serves as an intelligent life safety component for commercial and industrial fire protection systems. This unit installs directly into compatible addressable fire alarm control panels to provide comprehensive threat assessment by combining photoelectric smoke and carbon monoxide (CO) sensing within a single housing.\u003c\/p\u003e \u003cp\u003eDesigned to satisfy stringent life safety requirements under applicable codes such as \u003cstrong\u003eNFPA 72\u003c\/strong\u003e for fire alarm and signaling systems, this detector ensures precise threat identification and point ID capability. Facility managers and technicians rely on its addressable architecture to pinpoint exact alarm or fault locations, satisfying code mandates for rapid notification and localized emergency response.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eMulti-Criteria Sensing:\u003c\/strong\u003e Integrates photoelectric smoke and carbon monoxide detection into one point to assess threats accurately.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIntelligent Addressability:\u003c\/strong\u003e Features integral communication that pinpoints the exact location of an alarm or fault within your fire protection layout.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePoint ID Capability:\u003c\/strong\u003e Utilizes intuitive rotary address switches for precise device configuration and exact location identification.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLow-Profile Housing:\u003c\/strong\u003e Incorporates a modern, unobtrusive white design that blends seamlessly into commercial architectural ceilings.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFPC-951\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eLow-profile white housing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eAlways verify local Authority Having Jurisdiction (AHJ) requirements and consult manufacturer specifications before installation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903716184312,"sku":"FA-963-2","price":186.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-fpc-951-addressable-multi-criteria-photo-and-carbon-monoxide-detector-5569690.png?v=1775960921"},{"product_id":"notifier-sdx-551h-smoke-detector","title":"Notifier - SDX-551H - Smoke Detector","description":"\u003cdiv\u003e\u003cdiv\u003e \u003cp\u003eThe Notifier SDX-551H is an analog, addressable, low-profile photoelectronic smoke detector engineered for integration into commercial fire alarm signaling systems. Designed to mount directly to compatible system bases, it continuously monitors protected areas for products of combustion, utilizing advanced photoelectronic sensing chambers to provide early and reliable fire detection while minimizing false alarms.\u003c\/p\u003e \u003cp\u003eThis life safety device complies with stringent installation parameters mandated by NFPA 72 for national fire alarm and signaling code requirements, ensuring addressable system compatibility, precise device identification at the control panel, and dependable operational performance across commercial facilities.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eAddressable Technology:\u003c\/strong\u003e Communicates precise individual device status and analog smoke values directly to the main fire alarm control panel.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePhotoelectronic Sensing:\u003c\/strong\u003e Employs an optical sensing chamber optimized to detect slow-smoldering fires and smoke particles effectively.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eLow-Profile Design:\u003c\/strong\u003e Maintains a streamlined, unobtrusive architectural footprint on ceilings while housing advanced internal circuitry.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStandard Base Compatibility:\u003c\/strong\u003e Installs easily onto standard Notifier addressable mounting bases for fast retrofits and new installations.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-In Status Indicators:\u003c\/strong\u003e Features integrated LED indicators that display detector operational status during normal monitoring and alarm conditions.\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e \u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse: collapse;\"\u003e \u003cthead\u003e \u003ctr style=\"background-color: #f2f2f2;\"\u003e \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSDX-551H\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAnalog Addressable Photoelectronic Smoke Detector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eOperating Technology\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePhotoelectronic \/ Optical Sensing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eTwist-lock plug-in base (Base sold separately)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, ULC Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cem\u003eSubmittal \u0026amp; Installation Note: Contractors must verify local Authority Having Jurisdiction (AHJ) requirements, system panel compatibility, and engineering specifications prior to installation. Always consult the manufacturer's official technical data sheets for complete wiring diagrams and configuration parameters.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e\u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903717691640,"sku":"FA-079","price":233.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-sdx-551h-smoke-detector-5119808.jpg?v=1776485771"},{"product_id":"notifier-nbg-12lx-pull-station","title":"Notifier NBG-12LX Pull Station","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier NBG-12LX is a dual-action addressable manual pull station engineered for integration with compatible Notifier intelligent fire alarm control panels. Installed directly onto Signaling Line Circuits (SLC) in commercial and industrial life safety systems, this unit provides precise point identification, allowing the control panel to display the exact physical location of an alarm activation to emergency responders.\u003c\/p\u003e \u003cp\u003eThis life safety device complies with the mandates set forth in \u003cstrong\u003eNFPA 72\u003c\/strong\u003e for initiating device circuits and manual fire alarm boxes, ensuring reliable signal transmission and adherence to national fire code testing and installation requirements.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eMaterial Construction:\u003c\/strong\u003e Durable red polycarbonate body designed for high visibility and impact resistance in indoor environments.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOperating Mechanism:\u003c\/strong\u003e Dual-action push-in and pull-down design prevents accidental activations while meeting ADAAG section 4.1.3(13) and UL 38 standards requiring a maximum activation force of 5 lbs.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAddressable Communication:\u003c\/strong\u003e Built-in addressable interface module features rotary decimal switches for fast, precise zone programming on the SLC loop.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAccessibility:\u003c\/strong\u003e Features raised Braille text on the handle for compliance with accessibility guidelines.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Key-operated reset mechanism allows authorized personnel to restore the station efficiently after a test or event.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e\n\u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHoneywell \/ Notifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNBG-12LX\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSLC Loop (Screw Terminals)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTemperature Rating \/ Response Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e32°F to 120°F (0°C to 49°C) \/ Addressable Initiating Device\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePolycarbonate (Red)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/table\u003e \u003cp\u003eContractors and facility managers must verify all local Authority Having Jurisdiction (AHJ) mandates and compatibility with existing system architecture prior to system programming and deployment.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903717953784,"sku":"FA-612-2","price":105.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-nbg-12lx-pull-station-4634251.png?v=1776652733"},{"product_id":"notifier-honeywell-fsco-951-carbon-monoxide-detector","title":"Notifier Honeywell FSCO-951 Carbon Monoxide Detector","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier Honeywell FSCO-951 is an intelligent, addressable carbon monoxide detector designed to provide exact point location for alarm communication and selective maintenance within commercial fire alarm systems. This component integrates directly into your addressable fire system to satisfy life safety carbon monoxide code requirements in areas containing fuel-burning equipment, such as furnace rooms and laundry spaces. By delivering integral communication without requiring additional modules, the unit streamlines installation and gives technicians precise device tracking.\u003c\/p\u003e \u003cp\u003eThis life safety device complies with the \u003cstrong\u003eUL 2075\u003c\/strong\u003e standard for system-connected carbon monoxide detection (with the FSCO-951A variant meeting Canadian standard \u003cstrong\u003eCAN\/ULC-S588\u003c\/strong\u003e), ensuring full code compliance for commercial life safety installations.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eAddressable Point ID:\u003c\/strong\u003e Rotary address switches allow you to set exact device locations directly on the unit.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eModular Elimination:\u003c\/strong\u003e Built-in addressable communication removes the need for extra modules to streamline installation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eModern Design:\u003c\/strong\u003e Expanded color options and a contemporary aesthetic support modern architectural demands.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMaintenance Efficiency:\u003c\/strong\u003e Constructed for straightforward installation and selective system maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e\n\u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNotifier Honeywell\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFSCO-951 \/ FSCO-951A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed (UL 2075) \/ CAN\/ULC-S588\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003cp\u003eVerify all local Authority Having Jurisdiction (AHJ) mandates and consult the manufacturer technical data sheets before beginning installation on your fire alarm loop.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903718117624,"sku":"FA-038","price":145.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-honeywell-fsco-951-carbon-monoxide-detector-4395803.png?v=1776485776"},{"product_id":"notifier-fmm-1-addressable-monitor-module","title":"Notifier FMM-1 Addressable Monitor Module","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier FMM-1 Addressable Monitor Module supervises dry-contact input devices and reports status updates directly to your fire alarm control panel. It installs within commercial fire alarm systems to monitor critical life safety components like water flow switches, manual pull stations, and sprinkler system tamper switches.\u003c\/p\u003e \u003cp\u003eThis module satisfies critical commercial life safety requirements governed by NFPA 72 for fire alarm signaling systems, ensuring reliable point reporting and device supervision. Installers rely on its compliance-grade communication to maintain code-mandated system integrity across new construction and retrofit applications.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eCompact Design:\u003c\/b\u003e The space-saving footprint fits easily into tight locations, including electrical boxes directly behind monitored devices.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eFlashScan Protocol:\u003c\/b\u003e High-speed communication delivers rapid response times across Notifier intelligent fire alarm control panels.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eSingle Input Monitoring:\u003c\/b\u003e Supervises one initiating-device circuit containing normally open dry-contact alarm or supervisory devices. This is one monitored circuit, not a one-device limit; connected devices report through the module’s address.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eVisual LED Indicator:\u003c\/b\u003e Flashes during polling and lights steadily upon activation to simplify technician testing and maintenance.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eFlexible Mounting:\u003c\/b\u003e Includes a dedicated mounting plate for straightforward surface installation.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e\n\u003ctable\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eFMM-1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eUL Listed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/table\u003e \u003cp\u003eVerify all local Authority Having Jurisdiction (AHJ) requirements and consult manufacturer installation guidelines for the permitted circuit wiring, electrical-box mounting, and distance limits of the selected application.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e \u003ca href=\"#\"\u003eDownload Manufacturer Technical Data \u0026amp; Cut Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903718215928,"sku":"FA-476","price":59.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-fmm-1-addressable-monitor-module-9879325.png?v=1776652736"},{"product_id":"notifier-fsp-851r-smoke-detector","title":"Notifier FSP-851R Smoke Detector","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier FSP-851R is an intelligent, addressable photoelectric plug-in smoke detector engineered for commercial life safety systems. Designed for integration within commercial fire alarm networks—specifically compatible with Notifier ONYX series fire alarm control panels (FACPs) and authorized duct detector housings—this device mounts directly onto compatible bases to provide continuous, high-reliability smoke detection across diverse building spaces. Operating within a 24-volt SLC loop, the detector features an advanced optical sensing chamber built to identify smoke generated by a wide variety of combustion sources while minimizing false alarms.\u003c\/p\u003e \u003cp\u003eAdhering to strict life safety system criteria, this unit facilitates code-compliant monitoring under NFPA 72 standards for automatic fire detection systems. Point ID capability and decimal rotary address switches allow technicians to assign exact physical addresses to every detector on the loop. The control panel continuously software-monitors detector sensitivity and chamber status, ensuring rapid fault reporting and targeted maintenance before environmental dust or contamination compromises system integrity.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eIntelligent Photoelectric Sensing:\u003c\/strong\u003e Engineered optical chamber reliably detects smoke particles from smoldering and flaming fires while reducing nuisance alarms.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRemote Test Capability:\u003c\/strong\u003e Specifically designed for integration with DNR(W) duct detector housings to simplify routine testing and maintenance procedures.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePoint ID Addressing:\u003c\/strong\u003e Built-in rotary decimal address switches allow precise zone and location identification at the fire alarm control panel.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSoftware-Managed Sensitivity:\u003c\/strong\u003e Allows programmable sensitivity adjustments through the FACP to suit specific environmental conditions and occupancy types.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e360-Degree Visibility:\u003c\/strong\u003e Dual integrated LEDs flash to provide clear status visualization from any angle around the device.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eCompliance \/ Detail\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHoneywell \/ Notifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFSP-851R \/ 851 Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Mounting Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePlug-in base compatible (Standard \/ Duct Housing)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e15 to 32 VDC peak\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e300 µA max. average @ 24 VDC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e6.5 mA max. @ 24 VDC (LED on)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSensor Technology\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePhotoelectric with Integral Analog Communication\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003e\u003cem\u003eContractor Note: Verify compatibility with existing fire alarm control panel firmware versions and local Authority Having Jurisdiction (AHJ) requirements prior to system programming and device commissioning.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903718543608,"sku":"FA-049","price":93.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-fsp-851r-smoke-detector-3548380.png?v=1776485777"},{"product_id":"notifier-frm-1-addressable-relay-module-white","title":"Notifier FRM-1 Addressable Relay Module - White","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier FRM-1 Addressable Relay Module functions as a critical system interface for integrating and controlling auxiliary equipment within intelligent fire alarm assemblies. Installed directly onto the Signaling Line Circuit (SLC) loop of a compatible Notifier system, this component provides addressable dry-contact outputs to automate life safety responses—such as activating smoke control dampers, releasing magnetic door holders, shutting down air handling units, or switching 24V NAC power and audio signals up to 70.7 Vrms.\u003c\/p\u003e \u003cp\u003eEngineered to satisfy stringent life safety design requirements, this module operates in compliance with NFPA 72 standards for fire alarm signaling systems. It ensures reliable emergency coordination by utilizing high-speed FlashScan communication protocols and built-in type identification, allowing the main control panel to automatically recognize and supervise the auxiliary relay without complex manual configuration.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cb\u003eAddressable Dry-Contact Output:\u003c\/b\u003e Provides two Form-C dry contacts that switch together in response to a programmed or manual panel command. The contacts are not independently programmable outputs, and the module does not supervise their load-circuit wiring. \u003cb\u003eFlashScan® Communication Protocol:\u003c\/b\u003e Delivers communication speeds over five times faster than traditional methods to prioritize devices with updated information. \u003cb\u003eSLC Loop Powered:\u003c\/b\u003e Operates directly off the two-wire Signaling Line Circuit loop to simplify wiring and eliminate the need for dedicated power infrastructure. \u003cb\u003eIntegral LED Indicator:\u003c\/b\u003e Blinks green during normal panel communication and illuminates steady red upon activation for rapid visual troubleshooting. \u003cb\u003eHigh Noise Immunity:\u003c\/b\u003e Built with robust shielding against electromagnetic (EMF) and radio-frequency interference (RFI) to ensure stable performance in harsh electrical environments. \u003cb\u003eSEMS Screw Terminals:\u003c\/b\u003e Equipped with clamping plates to facilitate secure, reliable wire connections during rough-in and trim-out phases. \u003cb\u003eDirect-Dial Addressing:\u003c\/b\u003e Supports rotary dial entry for addresses 01–159 in FlashScan loops and 01–99 in CLIP mode loops.\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cb\u003eTechnical Field\u003c\/b\u003e\u003c\/th\u003e \u003cth\u003e\u003cb\u003eProduct Specification\u003c\/b\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eManufacturer \/ Brand\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eModel \/ Series Number \/ SIN\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eFRM-1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eTwo-Wire SLC Loop \/ SEMS Screw Terminals\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eMaterial \/ Body Construction\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eStandard Electronic Module Enclosure (White)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eAgency Listings \u0026amp; Approvals\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eApplicable NFPA Standards\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eContractors and facility managers must verify local Authority Having Jurisdiction (AHJ) requirements and consult the manufacturer's technical data sheets and engineering manuals prior to system programming and installation.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903719067896,"sku":"FA-484","price":116.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-frm-1-addressable-relay-module-white-4786859.png?v=1776009072"},{"product_id":"notifier-fsp-951-iv-smoke-detector-ivory","title":"Notifier FSP-951-IV Smoke Detector - Ivory","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier FSP-951-IV is a plug-in addressable-analog smoke sensor designed for commercial fire alarm and life safety systems. Integrating a photoelectronic sensing chamber, this unit transmits precise analog smoke density readings directly to a compatible fire control panel via a communication line. It installs seamlessly into fire protection assemblies to safeguard open areas and is officially listed for reliable operation within air duct applications, satisfying standard life safety requirements.\u003c\/p\u003e \u003cp\u003eSet device addresses quickly on the job site using the built-in rotary dial switches. The sensor supports both FlashScan and CLIP communication modes for flexible system integration. It features visible LED indicators to communicate operational statuses clearly during routine inspections.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eOperating Voltage:\u003c\/b\u003e Powers efficiently on a 15 to 32 VDC range.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eAir Velocity Rating:\u003c\/b\u003e Operates reliably in air speeds up to 4,000 feet per minute.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCompact Profile:\u003c\/b\u003e Measures 6.2 inches in diameter and 2.0 inches in height when installed in a B300-6 base.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eLightweight Build:\u003c\/b\u003e Weighs only 3.4 ounces for straightforward overhead installation.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/th\u003e \u003cth\u003e\u003cb\u003eDetail\u003c\/b\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eManufacturer \/ Brand\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eModel \/ Series Number \/ SIN\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eFSP-951-IV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003ePlug-in (Compatible with B300-6 and B501 bases)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eTemperature Rating \/ Response Type\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e32°F to 122°F (0°C to 50°C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eMaterial \/ Body Construction\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eIvory Plug-in Smoke Sensor\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eAgency Listings \u0026amp; Approvals\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eDuct Applications Listed\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eAlways verify local Authority Having Jurisdiction (AHJ) requirements and consult manufacturer technical data sheets before beginning installation.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903719362808,"sku":"FA-487","price":151.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-fsp-951-iv-smoke-detector-ivory-9377387.png?v=1776652749"},{"product_id":"notifier-fst-951-iv-heat-detector-ivory","title":"Notifier FST-951-IV Heat Detector - Ivory","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier FST-951-IV Heat Detector delivers precise thermal fire protection for environments where traditional smoke detectors trigger false alarms. This intelligent device installs directly into life safety assemblies, providing reliable early warning in dusty workshops, steamy kitchens, and smoky industrial areas.\u003c\/p\u003e \u003cp\u003eThis heat detector satisfies strict life safety requirements for commercial and residential fire protection systems. It complies with mandated industry regulations, holding rigorous certifications to ensure reliable performance during emergency responses.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eDual Sensing Technology:\u003c\/b\u003e Utilizes both fixed temperature and rate-of-rise sensing to accurately detect abnormal heat changes while cutting down nuisance alarms.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003ePrecise Thresholds:\u003c\/b\u003e Operates with 135°F (57°C) or 190°F (88°C) fixed temperature settings for optimal deployment across varying ambient conditions.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eLow-Profile Design:\u003c\/b\u003e Features a sleek, contemporary ivory casing that blends discreetly into modern interior ceilings.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eRotary Addressing:\u003c\/b\u003e Equipped with an intuitive rotary decimal switch for straightforward individual detector identification and precise control panel mapping.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003ePanel Compatibility:\u003c\/b\u003e Fully supports both FlashScan and CLIP Mode protocols for seamless communication with intelligent Notifier fire alarm control panels.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cb\u003eSpecification Field\u003c\/b\u003e\u003c\/th\u003e \u003cth\u003e\u003cb\u003eDetails\u003c\/b\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eManufacturer \/ Brand\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eModel \/ Series Number \/ SIN\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eFST-951-IV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eTemperature Rating \/ Response Type\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e135°F (57°C) or 190°F (88°C) Fixed Temperature \/ Rate-of-Rise\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eMaterial \/ Body Construction\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eIvory Casing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eAgency Listings \u0026amp; Approvals\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eApplicable NFPA Standards\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNFPA Compliant\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eVerify local Authority Having Jurisdiction (AHJ) requirements and consult manufacturer technical data sheets before beginning installation.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903720018168,"sku":"FA-560-2","price":162.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-fst-951-iv-heat-detector-ivory-5586113.png?v=1776009088"},{"product_id":"notifier-fpti-951-iv-multi-criteria-smoke-detector-ivory","title":"Notifier FPTI-951-IV Multi-Criteria Smoke Detector - Ivory","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier FPTI-951-IV Multi-Criteria Smoke Detector is an intelligent addressable initiation device designed for commercial and institutional fire alarm systems. Installed directly into fire alarm signaling line circuits, it integrates photoelectric, thermal, and infrared (PTIR) sensors into a single unit to monitor protected areas for actual fire signatures while minimizing nuisance alarms from dust, humidity, or cooking fumes.\u003c\/p\u003e \u003cp\u003eThis life safety component complies with NFPA 72 requirements for fire alarm system installation, testing, and maintenance. It satisfies strict modern testing standards including UL 268 7th Edition and UL 521, ensuring verified performance against flaming and smoldering polyurethane foam threats as well as cooking nuisance triggers. Canadian installations meet CAN\/ULC S529 and CAN\/ULC S530 listings.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003ePTIR Sensor Integration:\u003c\/b\u003e Combines photoelectric, thermal, and infrared detection technologies to identify multiple components of a fire.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eProtocol Compatibility:\u003c\/b\u003e Supports high-speed FlashScan and CLIP communication protocols for seamless integration with Notifier addressable fire alarm control panels.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eAddressable Configuration:\u003c\/b\u003e Features rotary address switches for quick, precise device addressing during job-site installation and routine maintenance.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eStatus Visibility:\u003c\/b\u003e Equipped with dual LEDs providing 360-degree omnidirectional visual status indication during walk-tests and emergencies.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eLow-Profile Aesthetic:\u003c\/b\u003e Utilizes a modern, low-profile design finished in ivory to blend discreetly into commercial interiors.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eElectrical Efficiency:\u003c\/b\u003e Built with a low standby current to minimize power consumption across the system loop.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e\n\u003ctable\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eFPTI-951-IV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003ePlug-in Addressable Base\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTemperature Rating \/ Response Type\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eMulti-Criteria Photoelectric, Thermal, Infrared (PTIR)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eIvory Finish Housing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eUL Listed, CAN\/ULC Listed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/th\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/table\u003e \u003cp\u003eVerify all local Authority Having Jurisdiction (AHJ) guidelines and consult the manufacturer technical specifications before commencing installation.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903720345848,"sku":"FA-458","price":349.79,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-fpti-951-iv-multi-criteria-smoke-detector-ivory-5443478.png?v=1776009093"},{"product_id":"notifier-mmx-101-addressable-mini-monitor-module","title":"Notifier MMX-101 Addressable Mini Monitor Module","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier MMX-101 Addressable Mini Monitor Module provides a reliable two-wire, Style B (Class B) initiating circuit for normally-open contact fire alarm and supervisory devices. Designed for seamless integration into intelligent fire alarm control panel systems, this compact unit mounts directly inside a single-gang junction box right behind the monitored device. Its minimal footprint and lightweight profile eliminate the need for rigid structural mounting, making it well-suited for retrofits and tight installation spaces where traditional modules will not fit.\u003c\/p\u003e \u003cp\u003eEngineered to comply with applicable NFPA 72 requirements for fire alarm signaling systems, the MMX-101 ensures addressable point identification for life safety monitoring devices such as waterflow switches, tamper switches, and manual pull stations. It transmits critical status changes back to the main control panel to maintain strict code compliance and system reliability across commercial and industrial facilities.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Small physical dimensions allow direct installation within a standard single-gang junction box behind the monitored device.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCircuit Configuration:\u003c\/strong\u003e Provides a Style B (Class B) initiating device circuit for normally-open (N.O.) dry contact devices.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlexible Deployment:\u003c\/strong\u003e Lightweight design permits wire-based placement without requiring rigid mechanical mounting brackets.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Fully addressable and designed to interface with compatible Notifier fire alarm control panels.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMMX-101\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePigtail wire leads for SLC and initiating device loops\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eOperating Circuit Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eStyle B \/ Class B (Normally-Open Contacts)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaximum Installation Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e120°F (49°C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eBody Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHigh-impact molded plastic housing with integrated wire leads\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eContractors must verify all local Authority Having Jurisdiction (AHJ) requirements and consult the manufacturer's technical data sheets and installation manuals prior to wiring and commissioning this device.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903720476920,"sku":"FA-828-2","price":104.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-mmx-101-addressable-mini-monitor-module-2606765.png?v=1776652774"},{"product_id":"fire-lite-notifier-rel-47k-end-of-line-resistor","title":"Fire-lite Notifier REL-47K End of Line Resistor","description":"\u003cdiv\u003e\n\u003cp\u003eThe Fire-lite Notifier REL-47K End of Line Resistor maintains critical circuit supervision in commercial life safety and fire alarm control panel installations. Installed at the terminal point of initiating device circuits or notification appliance circuits, this supervisory component allows the control panel to continuously monitor wiring integrity, instantly alerting technicians to open or short-circuit faults. This hardware component supports strict code compliance under NFPA 72 requirements for initiating device circuit supervision, ensuring your life safety system remains fully operational and code-compliant.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eResistance Rating:\u003c\/b\u003e 47K ohms engineered specifically for compatible Fire-Lite and Notifier alarm panels.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eIntegrated Leads:\u003c\/b\u003e Factory-attached leads allow for fast, secure connections directly into terminal blocks or wire nuts during rough-in and trim-out phases.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCircuit Integrity:\u003c\/b\u003e Facilitates continuous loop monitoring to detect opens and grounds before they compromise system response.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eProfessional Design:\u003c\/b\u003e Built for commercial fire protection contractors needing reliable end-of-line termination hardware.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFire-Lite \/ Notifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eREL-47K\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eResistance Value\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e47K Ohms\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eEnd of Line (EOL) Resistor\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAttached Leads\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFire Alarm Circuit Supervision\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eEnsure all device installations comply with local Authority Having Jurisdiction (AHJ) mandates and engineering drawings. Always review the compatible fire alarm control panel technical manual for exact zone wiring requirements prior to installation.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903720739064,"sku":"FA-780-2","price":18.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/fire-lite-notifier-rel-47k-end-of-line-resistor-3552397.png?v=1776652777"},{"product_id":"notifier-lcm-320-loop-controller-for-nfs2-3030","title":"Notifier LCM-320 Loop Controller for NFS2-3030","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier LCM-320 Loop Control Module serves as the critical communication backbone for Notifier ONYX® Series Fire Alarm Control Panels, specifically the NFS-3030 and NFS2-3030 models. It installs directly inside the fire alarm control panel enclosure to expand and enhance Signaling Line Circuit (SLC) capabilities, facilitating two-way communication and real-time monitoring of addressable devices such as smoke detectors, heat detectors, manual pull stations, and control modules.\u003c\/p\u003e \u003cp\u003eThis module satisfies critical life safety system requirements by maintaining system survivability and code-compliant operation under NFPA 72 guidelines. It features a built-in degraded mode that preserves alarm activation and communication functions even if the fire panel loses its master control function during a wiring fault or system disturbance.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eModular Expandability:\u003c\/b\u003e Allows NFS-3030 and NFS2-3030 panels to support up to five LCM-320 modules and five LEM-320 modules to scale addressable loops.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eExtended Loop Capacity:\u003c\/b\u003e Supports SLC wiring distances of up to 12,500 feet on a Class B twisted-unshielded loop for flexible facility layouts.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003ePlug-in Installation:\u003c\/b\u003e Streamlines setup inside the panel enclosure to reduce integration time and labor.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eDegraded Mode Operation:\u003c\/b\u003e Maintains critical life safety communications and alarm functions during master control loss or fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cb\u003eTechnical Parameter\u003c\/b\u003e\u003c\/th\u003e \u003cth\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eManufacturer \/ Brand\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eModel \/ Series Number\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eLCM-320 \/ ONYX® Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eCompatible Control Panels\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNFS-3030, NFS2-3030\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eMax SLC Wiring Distance\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e12,500 Feet (3,810 Meters)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eWiring Configuration\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eClass B (Style 4) Twisted-Unshielded Loop\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eMaximum Module Capacity\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eUp to 5 LCM-320s and 5 LEM-320s per FACP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eMounting Type\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003ePlug-in Panel Mount\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eApplicable NFPA Standards\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eVerify local Authority Having Jurisdiction (AHJ) requirements and consult the manufacturer technical data sheets and installation manuals prior to system programming and deployment.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903720771832,"sku":"FA-477","price":442.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-lcm-320-loop-controller-for-nfs2-3030-2402902.png?v=1776009105"},{"product_id":"notifier-hd-601-heat-detector","title":"Notifier HD-601 Heat Detector","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier HD-601 Heat Detector integrates combination rate-of-rise and fixed-temperature sensing to provide reliable fire alarm initiation within commercial life safety and fire suppression detection loops. Designed for ceiling installation in commercial and industrial facilities, this unit operates by identifying thermal signatures through pneumatic expansion and fusible alloy elements, ensuring prompt circuit closure when hazardous temperatures are reached.\u003c\/p\u003e \u003cp\u003eThis heat detector satisfies commercial fire alarm system requirements governed by applicable sections of NFPA 72 for initiating devices. The unit utilizes a pneumatic rate-of-rise element that triggers upon a temperature increase of approximately 15°F per minute, alongside a fusible alloy fixed-temperature response mechanism available in 135°F and 200°F ratings to ensure strict compliance with life safety design specifications.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eDual Detection:\u003c\/b\u003e Combines a pneumatic rate-of-rise element with a fixed-temperature fusible alloy for comprehensive thermal threat detection.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eVisual Indication:\u003c\/b\u003e The external heat collector drops away upon activation to provide immediate visual confirmation of operation.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eWide Spacing:\u003c\/b\u003e Rate-of-rise units feature a wide spacing allowance on 50-foot centers to maximize coverage area.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eLow-Profile Design:\u003c\/b\u003e Protrudes only 1-3\/8 inches from the ceiling surface when mounted to a junction box.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eAesthetic Finish:\u003c\/b\u003e Features pleasing contours and an all-white finish that blends seamlessly with standard ceiling tiles.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eElectrical Configuration:\u003c\/b\u003e Available in one- or two-circuit, normally open wiring configurations.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHD-601 (HD-600 Series)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Mounting Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eJunction Box Mounting\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e135°F (57°C) or 200°F (94°C)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eDurable housing with all-white finish and fusible alloy element\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eEnsure all device placements comply with local Authority Having Jurisdiction (AHJ) mandates and engineering design drawings before initiating installation. Refer strictly to the manufacturer technical data sheet for complete electrical wiring schematics and spacing rules.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":46903721001208,"sku":"FA-793-2","price":24.19,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-hd-601-heat-detector-7643514.png?v=1776652779"},{"product_id":"notifier-fdrm-1-dual-relay-monitor-module","title":"Notifier FDRM-1 Dual Relay Monitor Module","description":"\u003cdiv\u003e\n\u003cp\u003eThe Notifier FDRM-1 Dual Relay Monitor Module is an intelligent addressable component designed for commercial fire alarm and life safety systems. It installs directly into fire protection networks to combine control and monitoring capabilities into a single unit, saving panel space and reducing wiring complexity across your facility.\u003c\/p\u003e \u003cp\u003eThis module satisfies critical code compliance requirements for life safety signaling networks by integrating with intelligent two-wire signaling line circuits (SLCs). It is engineered to meet strict industry benchmarks, holding UL Listing and FM Approved certifications for fire alarm equipment to ensure reliable performance during an emergency event.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cb\u003eDual Functionality:\u003c\/b\u003e Combines two individual Form C relay control modules and two Class B monitor modules into one compact unit. \u003cb\u003eIntelligent Integration:\u003c\/b\u003e Connects to two-wire signaling line circuits for unique device identification and precise panel control. \u003cb\u003eForm C Relays:\u003c\/b\u003e Provides versatile switching for applications like door holder releases, fan shutdowns, or elevator recalls. \u003cb\u003eClass B Inputs:\u003c\/b\u003e Interfaces with normally open contact devices, such as waterflow or tamper switches. These are contact-monitoring inputs, not powered two-wire smoke-detector zones. \u003cb\u003eUser-Friendly Addressing:\u003c\/b\u003e Features visible rotary dials for TENS and ONES digits to quickly set the address directly on the unit.\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e\n\u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Field\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNotifier\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFDRM-1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eTwo-wire SLC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 72 (Fire Alarm Code)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eContractors must verify local Authority Having Jurisdiction (AHJ) requirements and consult the manufacturer technical data sheets before beginning installation.\u003c\/p\u003e \u003c\/div\u003e","brand":"Fredland Supply Company","offers":[{"title":"Default Title","offer_id":47054248214776,"sku":"FA-039","price":291.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/notifier-fdrm-1-dual-relay-monitor-module-9577851.png?v=1775963137"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/collections\/notifier-fire-alarm-system-9931641.png?v=1780310495","url":"https:\/\/fireprotectionparts.net\/collections\/fire-alarm.oembed?page=2","provider":"Fire Protection Parts","version":"1.0","type":"link"}