The 1-1/4" COMMERCIAL RISER X 1/2 L/PRESSURE REDUCING VALVE (PRV) is an essential component for enhancing the efficiency and safety of commercial fire sprinkler systems. Manufactured by Viking, this advanced assembly is specifically designed to meet NFPA 13 requirements, ensuring optimal compliance and reliability for your gridded systems. With its innovative features, this product significantly simplifies installation and maintenance processes while delivering superior performance.

Key Feature 1: Enhanced Installation Flexibility

This commercial riser is designed to eliminate the need to drain the system prior to installation of the pressure relief valve. This means quicker, hassle-free installations, saving you valuable time and effort.

Key Feature 2: Hydrostatic Testing Made Easy

Equipped with a built-in test port, the 1-1/4" COMMERCIAL RISER X 1/2 L/PRESSURE REDUCING VALVE (PRV) allows for hydrostatic testing without the inconvenience of draining the entire system. This feature not only saves time but also maximizes resource efficiency during maintenance.

Key Feature 3: Comprehensive Field Replaceability

Designed with standard components that can be easily replaced in the field, including pressure gauges and a Potter flow switch, this valve ensures minimal downtime and promotes efficient operation, making it a practical choice for facility managers and contractors.

Reason to Choose This Product

The 1-1/4" COMMERCIAL RISER X 1/2 L/PRESSURE REDUCING VALVE (PRV) is more than just a component; it's an investment in safety and efficiency. Its unique features enhance safety compliance and streamline installation and maintenance processes, making it a reliable choice for any commercial fire protection system. Choose this advanced solution for peace of mind and optimal performance in your fire safety systems.

The 1-1/4" COMMERCIAL RISER X 1/2 L/PRESSURE REDUCING VALVE (PRV) is a top-tier solution designed to enhance the efficiency and safety of commercial fire sprinkler systems. Manufactured by Viking, this assembly meets NFPA 13 requirements, ensuring compliance and reliability for your gridded systems. With its innovative design, it significantly simplifies installation and maintenance processes while offering superior performance.

Main Advantage 1: Enhanced Installation Flexibility

This commercial riser features a configuration that eliminates the need to drain the system before installing the pressure relief valve, allowing for quicker and hassle-free installation.

Main Advantage 2: Hydrostatic Testing Made Easy

Equipped with a built-in test port, the 1-1/4" COMMERCIAL RISER X 1/2 L/PRESSURE REDUCING VALVE (PRV) allows for hydrostatic testing without needing to drain the entire system, saving time and resources during maintenance.

Main Advantage 3: Comprehensive Field Replaceability

Designed with standard components that can be easily replaced in the field, including pressure gauges and a Potter flow switch, this product ensures minimal downtime and efficient operation.

Why this product is a must-have:

The 1-1/4" COMMERCIAL RISER X 1/2 L/PRESSURE REDUCING VALVE (PRV) is essential for any commercial fire sprinkler system. Its unique features not only enhance safety compliance but also streamline installation and maintenance processes, making it a reliable choice for contractors and facility managers alike. Invest in efficiency and peace of mind with this advanced solution.

Brand: Viking

Viking EasyPac Commercial Riser Manifold Assemblies are available in sizes 1-1/4”, 1-1/2”, 2”, 2-1/2”, 3”, 4”, 6” and 8” for commercial systems. They are available with an AGF TESTanDRAIN valve, and/or pressure relief valve (PRV) to meet NFPA 13 requirements for gridded systems and any system requiring a pressure relief valve. This configuration eliminates the need to drain the system before installing the relief valve, while a built in test port allows hydrostatic testing without draining the system.

EasyPac Commercial Assemblies are designed with all required equipment and standard components that can be replaced in the field, including pressure gauges, Potter flow switches, 3-way gauge control valve and appropriate drain valve. All assemblies are available in grooved inlet and outlet connections 1-1/4”-8” using Schedule 10 steel pipe. The 1-1/4” to 2” assemblies are also available with male NPT threaded inlets and outlets, or threaded inlets x grooved outlets using Schedule 40 steel pipe.

TECHNICAL DATA SHEET


More Information
Item Number 8312AS
Brand AGF Manufacturing
Box Quantity 1

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.