{"product_id":"1-to-8-telescoping-pipe-stand-for-pipe-support-system","title":"1\" to 8\" Telescoping Pipe Stand for Pipe Support System","description":"\u003cdiv\u003e\n\u003cp\u003eThe 1\" to 8\" Telescoping Pipe Stand is a robust support component engineered specifically for commercial, industrial, and large residential fire protection and mechanical piping systems. Installed within horizontal piping layouts, this adjustable stand secures pipe runs and manages vertical alignment to maintain structural integrity across complex networks. In compliance with industry standards for fire sprinkler and mechanical infrastructure, it satisfies mandatory code requirements for secure, stable pipe fastening and minimizes system movement during active facility operations.\u003c\/p\u003e \u003cp\u003eDesigned to mitigate the risks of uneven surfaces and variable installation heights, this assembly incorporates a reliable telescoping lock that allows for rapid adjustments without requiring extra tools. Its heavy-duty construction securely supports various pipe diameters, while the protective corrosion-resistant finish withstands moisture and harsh environmental conditions for both indoor and outdoor service. By absorbing operational vibrations and reducing pipe displacement, the stand preserves long-term system reliability.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eAdjustable Height Range:\u003c\/b\u003e Smoothly extends from 1 inch to 8 inches for customized, precise pipe positioning.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eHeavy-Duty Construction:\u003c\/b\u003e Manufactured from durable materials to secure heavy runs and suppress operational vibrations.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCorrosion-Resistant Finish:\u003c\/b\u003e Features a protective coating to resist moisture degradation in indoor and outdoor environments.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eSecure Locking Mechanism:\u003c\/b\u003e Integrates a reliable telescoping lock to streamline adjustments and lock in stable support.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eWide Compatibility:\u003c\/b\u003e Accommodates various pipe diameters and materials across diverse mechanical and fire sprinkler layouts.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003enVent CADDY\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1\"-8\" TELESCOPING PIPE STAND EG\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePressure Rating (WWP \/ Max Working Pressure)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eK-Factor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTemperature Rating \/ Response Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHeavy-Duty Steel with Corrosion-Resistant Finish\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 13 (Standard for the Installation of Sprinkler Systems)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eAlways verify local Authority Having Jurisdiction (AHJ) mandates and consult the manufacturer's official engineering data sheets prior to job site installation.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e \u003ca href=\"#\"\u003eDownload Manufacturer Technical Data \u0026amp; Cut Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"nVent CADDY","offers":[{"title":"Default Title","offer_id":46372718379256,"sku":"CTS04","price":320.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/1-to-8-telescoping-pipe-stand-for-pipe-support-system-6577115.jpg?v=1775620880","url":"https:\/\/fireprotectionparts.net\/products\/1-to-8-telescoping-pipe-stand-for-pipe-support-system","provider":"Fire Protection Parts","version":"1.0","type":"link"}