{"product_id":"reliable-kfr56-intermediate-pendent-fire-sprinkler-165f-212f","title":"Reliable KFR56 Intermediate Pendent Fire Sprinkler | 165°F \u0026 212°F","description":"\u003cdiv\u003e\u003cdiv\u003e \u003ch2\u003eOverview\u003c\/h2\u003e \u003cp\u003eThe Reliable KFR56 Intermediate Pendent Fire Sprinkler is engineered for intermediate-level installation within commercial fire suppression systems. This component integrates into wet pipe or similar automatic fire sprinkler assemblies where water shielding is required to protect lower levels from water discharge or to activate secondary heads in multi-tier arrangements. It operates by thermally releasing its internal element at specific temperature thresholds to distribute water effectively across the hazard area.\u003c\/p\u003e \u003cp\u003eTo maintain strict life safety compliance, this sprinkler must be installed in accordance with NFPA 13 standards and the specific engineered system design. Contractors must verify approved installation arrangements, the exact thread standard, and the required water shield or guard\/shield configuration to satisfy Authority Having Jurisdiction (AHJ) mandates.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003ePrecision Temperature Options:\u003c\/b\u003e Choose between 165°F (Model KFR56PI1B) and 212°F (Model KFR56PI2B) ratings to match your specific environmental heat thresholds.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eStandard Connection Size:\u003c\/b\u003e Features a listed ½-inch connection for secure integration into existing piping networks.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eIntermediate Configuration:\u003c\/b\u003e Designed for multi-tier or rack storage applications requiring intermediate water shields and guards.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eJob Site Versatility:\u003c\/b\u003e Selectable ordering codes allow you to match the exact manufacturer part number, finish, and sprinkler identification number required by your project specifications.\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e \u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e \u003cthead\u003e \u003ctr style=\"background-color: #f2f2f2;\"\u003e \u003cth\u003e\u003cb\u003eTechnical Parameter\u003c\/b\u003e\u003c\/th\u003e \u003cth\u003e\u003cb\u003eSpecification Details\u003c\/b\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eManufacturer \/ Brand\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eReliable Sprinkler\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eModel \/ Series Number \/ SIN\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eKFR56 Intermediate Pendent (KFR56PI1B \/ KFR56PI2B)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e½-inch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003ePressure Rating (WWP)\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eK-Factor\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eTemperature Rating \/ Response Type\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003e165°F (KFR56PI1B) \/ 212°F (KFR56PI2B)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eMaterial \/ Body Construction\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eAgency Listings \u0026amp; Approvals\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cb\u003eApplicable NFPA Standards\u003c\/b\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 13\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch2\u003eSubmittal \u0026amp; Installation Note\u003c\/h2\u003e \u003cp\u003eVerify all local AHJ requirements, thread standards, water shield configurations, and complete manufacturer part numbers before purchasing or installing this assembly. \u003ca href=\"#\"\u003eConsult Reliable’s product catalog and list price book\u003c\/a\u003e as a general ordering reference, then obtain the exact configuration’s technical and installation requirements.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e \u003ca href=\"#\"\u003eDownload Manufacturer Technical Data \u0026amp; Cut Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"Reliable Sprinkler","offers":[{"title":"1\/2-inch \/ Stainless Steel \/ 165F","offer_id":48342879600888,"sku":"KFR56PI1B","price":70.99,"currency_code":"USD","in_stock":true},{"title":"1\/2-inch \/ Stainless Steel \/ 212F","offer_id":48342879633656,"sku":"KFR56PI2B","price":70.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/reliable-model-kfr56-intermediate-pendent-k56-80-threads-12-15mm-ra3614-1896792.png?v=1778907189","url":"https:\/\/fireprotectionparts.net\/products\/reliable-kfr56-intermediate-pendent-fire-sprinkler-165f-212f","provider":"Fire Protection Parts","version":"1.0","type":"link"}