{"product_id":"reliable-model-g-r1015-k5-6-pendent-sprinkler-d1-codes","title":"Reliable Model G R1015 K5.6 Pendent Sprinkler | D1 Codes","description":"\u003cdiv\u003e\n\u003cp\u003eThe Reliable Model G R1015 is a standard-response pendent fire sprinkler engineered for commercial fire suppression assemblies. Installed in wet or dry pipe fire protection systems, this component deploys via a solder capsule thermal element to discharge water over a targeted hazard area upon reaching its rated temperature.\u003c\/p\u003e \u003cp\u003eTo satisfy life safety compliance, installations must adhere strictly to \u003cstrong\u003eNFPA 13\u003c\/strong\u003e design and installation standards. This ensures proper hydraulic calculations, unobstructed discharge patterns from the deflector, and correct temperature ratings for the specific hazard classification.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Features a robust brass-alloy frame, load screw, and deflector paired with a bronze-alloy cap and PTFE seal for long-term reliability.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e Rated for a maximum working pressure of 175 psi (12 bar) to accommodate standard commercial fire main demands.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHydraulic Performance:\u003c\/strong\u003e Nominal K-factor of 5.6 (80 metric) ensures precise water distribution calculations.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThermal Response:\u003c\/strong\u003e Standard-response solder capsule thermal element provides dependable activation across commercial environments.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInstallation Tooling:\u003c\/strong\u003e Compatible with Model W2 tools for standard pendent installation and Model RC1 tools for approved recessed configurations.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eReliable Sprinkler (RASCO)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eModel G \/ R1015\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1\/2-inch NPT or ISO 7-R½\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePressure Rating (WWP)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e175 psi (12 bar)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eK-Factor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e5.6 (80 metric)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTemperature Rating \/ Response Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e135°F, 165°F, and 286°F \/ Standard Response\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBrass-alloy frame, load screw, deflector; bronze-alloy cap with PTFE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 13\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eVerify all local Authority Having Jurisdiction (AHJ) mandates, building codes, and project specifications regarding temperature ratings, thread standards, and accessory limitations before commencing work. Note that the 286°F temperature rating and specific guards\/shields are restricted from recessed installations.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e \u003ca href=\"#\"\u003eDownload Manufacturer Technical Data \u0026amp; Cut Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Reliable Sprinkler","offers":[{"title":"1\/2-inch \/ Brass \/ 165F","offer_id":48342478881016,"sku":"GP1BD1","price":71.99,"currency_code":"USD","in_stock":true},{"title":"1\/2-inch \/ Standard \/ 135F","offer_id":48342478913784,"sku":"GP0BD1","price":71.99,"currency_code":"USD","in_stock":true},{"title":"1\/2-inch \/ Standard \/ 286F","offer_id":48342478946552,"sku":"GP3BD1","price":71.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/reliable-pendent-fire-sprinkler-k56-12-thread-r1015-1682657.png?v=1779725747","url":"https:\/\/fireprotectionparts.net\/products\/reliable-model-g-r1015-k5-6-pendent-sprinkler-d1-codes","provider":"Fire Protection Parts","version":"1.0","type":"link"}