{"product_id":"steel-flange-adapter-assembly-eg-for-1-4-to-3-4-flange","title":"Steel Flange Adapter Assembly EG for 1\/4\" to 3\/4\" Flange","description":"\u003cdiv\u003e\n\u003cp\u003eThe nVent CADDY Steel Flange Adapter Assembly EG is engineered for structural support, fire protection, and seismic bracing systems. It installs directly onto structural flanges to secure bracing assemblies and maintain structural integrity under dynamic operational and seismic loads. By bridging varying structural dimensions, this adapter ensures the secure integration of misaligned components while reducing installation time on the job site.\u003c\/p\u003e \u003cp\u003eThis component supports life safety installations governed by standard industry guidelines, satisfying structural attachment and bracing requirements outlined in NFPA 13 for fire sprinkler systems and general seismic bracing protocols. It is designed to complement UL Listed and FM Approved fire protection hardware, ensuring code compliance and structural reliability during emergency events.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eMaterial Construction:\u003c\/strong\u003e Crafted from precision-grade ductile iron, providing mechanical strength and corrosion resistance in harsh industrial environments.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eFlange Compatibility:\u003c\/strong\u003e Accommodates structural flanges ranging from 1\/4 inch to 3\/4 inch for versatile application across multiple support configurations.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSecure Fastening:\u003c\/strong\u003e Features robust bolts and a precision fit to maintain leak-resistant, high-strength connections under dynamic mechanical stress.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e Weighs 3.63 lbs per individual unit, balancing heavy-duty load capacity with manageable field handling.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e \u003ccaption class=\"table-caption\"\u003eTechnical Specifications \u0026amp; Compliance\u003c\/caption\u003e \u003cthead\u003e \u003ctr\u003e \u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e \u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003enVent CADDY\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCSBS1A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1\/4\" to 3\/4\" Flange\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePressure Rating (WWP \/ Max Working Pressure)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eK-Factor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTemperature Rating \/ Response Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eDuctile Iron\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eDesigned to complement UL Listed and FM Approved components\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 13\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eContractors must verify local Authority Having Jurisdiction (AHJ) requirements regarding seismic bracing and structural attachment spacing prior to installation. Always consult the manufacturer's official technical cut sheets for torque specifications and load ratings.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e \u003ca href=\"#\"\u003eDownload Manufacturer Technical Data \u0026amp; Cut Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e\n\u003ccaption class=\"table-caption\"\u003eMore Information\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eItem Number\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Item Number\"\u003eCSBS1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Weight\"\u003e3.630000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eBox Quantity\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Box Quantity\"\u003e5.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCrate Quantity\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Crate Quantity\"\u003e5.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDescription\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Description\"\u003eSTEEL FLG ADAPTOR ASSEMBLY EG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Brand\"\u003enVent CADDY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003ePrice Group\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Price Group\"\u003eSR450.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003ePricing UOM\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Pricing UOM\"\u003eEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSearch Text\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Search Text\"\u003eSEISMIC BRACING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eVendor Part Number\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Vendor Part Number\"\u003eCSBS1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"nVent CADDY","offers":[{"title":"Default Title","offer_id":46372718117112,"sku":"CSBS1A","price":85.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/steel-flange-adapter-assembly-eg-for-14-to-34-flange-2908191.jpg?v=1775620877","url":"https:\/\/fireprotectionparts.net\/products\/steel-flange-adapter-assembly-eg-for-1-4-to-3-4-flange","provider":"Fire Protection Parts","version":"1.0","type":"link"}