{"product_id":"viking-vk510-k25-2-esfr-pendent-sprinkler","title":"Viking VK510 K25.2 ESFR Pendent Sprinkler","description":"\u003cdiv\u003e\n\u003cp\u003e\nThe Viking VK510 K25.2 ESFR Pendent Sprinkler is engineered for demanding industrial and commercial fire protection, especially suited for spaces with high-piled storage like warehouses and manufacturing facilities. Its advanced Early Suppression Fast Response technology ensures rapid activation and effective fire control where it’s most critical.\n\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eK-Factor 25.2\u003c\/b\u003e: Delivers a high-volume water discharge optimized for quickly suppressing large, high-challenge fires in storage environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eESFR Technology\u003c\/b\u003e: Provides early suppression and fast response to fire incidents, minimizing heat buildup and fire spread.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePendent Orientation\u003c\/b\u003e: Designed for ceiling installation to provide broad, targeted water coverage directly over fire-prone areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDurable Materials\u003c\/b\u003e: Constructed with corrosion-resistant metals to endure harsh industrial conditions and reduce maintenance needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIntegrated Protective Guard\u003c\/b\u003e: Shields sensitive sprinkler components from mechanical damage without interfering with water spray patterns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCertifications\u003c\/b\u003e: UL Listed and FM Approved, fully compliant with NFPA 13 ESFR standards for reliable code adherence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInstaSeal® Compatibility\u003c\/b\u003e: Select models support Torque-Assist caps, simplifying installation and improving seal integrity for maintenance efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003e\nThis sprinkler provides fast, reliable fire suppression to protect assets and maintain safety compliance in rigorous industrial settings. Its potent water discharge and early activation help prevent fire escalation, critical for facilities with tall storage racks and rapid flame spread hazards. The corrosion-resistant construction and protective guard ensure long-term performance and fewer replacements, lowering lifecycle costs. Designed for both new installations and upgrades, the Viking VK510 balances efficient operation with robust safety standards. Optional InstaSeal® compatibility streamlines installation workflows, making this sprinkler a practical choice for professionals managing fire protection in complex environments.\n\u003c\/p\u003e \u003cimg src=\"https:\/\/www.supplynet.com\/media\/.renditions\/wysiwyg\/InstaSeal_Compatible_Icon_-_1_000x1_000_File_1.png\" alt=\"InstaSeal Compatible\"\u003e\n\u003cimg src=\"https:\/\/www.supplynet.com\/media\/.renditions\/wysiwyg\/InstaSeal_Compatible_Icon_-_1_000x1_000_File_1.png\" alt=\"InstaSeal Compatible\"\u003e\n\u003cimg src=\"https:\/\/www.supplynet.com\/media\/.renditions\/wysiwyg\/InstaSeal_Compatible_Icon_-_1_000x1_000_File_1.png\" alt=\"InstaSeal Compatible\"\u003e \u003cbr\u003e \u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 20%; vertical-align: middle;\"\u003e\u003cimg width=\"125\" src=\"https:\/\/www.supplynet.com\/media\/.renditions\/wysiwyg\/InstaSeal_Compatible_Icon_-_1_000x1_000_File_1.png\" alt=\"InstaSeal Compatible\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80%; text-align: left; vertical-align: middle;\"\u003e\u003cem\u003eSelect models are compatible with revolutionary \u003cstrong\u003eInstaSeal® technology\u003c\/strong\u003e through the addition of Torque-Assist caps. This feature simplifies installation and enhances sealing performance. Please verify the InstaSeal® compatibility for your specific project requirements.\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e \u003cbr\u003e \u003ctable id=\"product-attribute-specs-table\" class=\"data table additional-attributes\"\u003e\n\u003ccaption class=\"table-caption\"\u003eTechnical Specifications\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eK-Factor\u003c\/th\u003e\n\u003ctd class=\"col data\"\u003e25.2 (363 metric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eResponse Type\u003c\/th\u003e\n\u003ctd class=\"col data\"\u003eESFR (Early Suppression Fast Response)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eOrientation\u003c\/th\u003e\n\u003ctd class=\"col data\"\u003ePendent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eCertifications\u003c\/th\u003e\n\u003ctd class=\"col data\"\u003eUL Listed, FM Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Viking","offers":[{"title":"Guard \/ 165 °F (74 °C)","offer_id":48200049000696,"sku":"12080ACG","price":49.96,"currency_code":"USD","in_stock":true},{"title":"Guard \/ 205 °F (96 °C)","offer_id":48200049033464,"sku":"12080AEG","price":49.96,"currency_code":"USD","in_stock":true},{"title":"Yes \/ 165 °F (74 °C)","offer_id":48200049066232,"sku":"12080AC-TQ","price":54.02,"currency_code":"USD","in_stock":true},{"title":"Yes \/ 205 °F (96 °C)","offer_id":48200049099000,"sku":"12080AE-TQ","price":54.02,"currency_code":"USD","in_stock":true},{"title":"No \/ 165 °F (74 °C)","offer_id":48200049131768,"sku":"12080AC","price":54.02,"currency_code":"USD","in_stock":true},{"title":"No \/ 205 °F (96 °C)","offer_id":48200049164536,"sku":"12080AE","price":54.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/7183\/3336\/files\/viking-vk510-k252-esfr-pendent-sprinkler-5505453.webp?v=1778907312","url":"https:\/\/fireprotectionparts.net\/products\/viking-vk510-k25-2-esfr-pendent-sprinkler","provider":"Fire Protection Parts","version":"1.0","type":"link"}