Reliable Sprinkler

Fire Protection Backflow Preventer WILKINS 475/475V OSY

Fire Protection Backflow Preventer WILKINS 475/475V OSY

Product code: 25475

Precio habitual $8,414.67
Precio habitual $17,409.65 Precio de oferta $8,414.67
51% OFF

Fast Shipping To USA & Canada

100% Satisfaction Guaranteed

365-Day Warranty

Description

The Wilkins 475/475V OSY is a Reduced Pressure Principle (RP) backflow preventer, not a Double Check Detector Assembly (DCDA). The initial product title mentioned "DCDA" which seems incorrect based on the search results. I will correct this in the description. The OSY refers to "Outside Stem and Yoke" gate valves, which provide a clear visual indication of whether the valve is open or closed, crucial for fire protection systems. Here's a breakdown of the information gathered for the description: Introduction: * What it is: Fire Protection Backflow Preventer, specifically a Reduced Pressure Principle (RP) assembly. * Who it's for: Building owners, facility managers, fire protection contractors, engineers. * Main appeal: Protects potable water supplies from contamination in fire sprinkler systems, ensures compliance, reliable operation. Key Features (Wilkins 475/475V OSY): * Reduced Pressure Principle (RP) Design: Provides the highest level of protection against both backsiphonage and backpressure, suitable for high-hazard applications. * OS&Y Gate Valves: Outside Stem and Yoke valves offer a clear visual indication of the valve's open or closed status, which is vital for quick inspections and ensuring system readiness in fire protection applications. * Durable Construction: Epoxy-coated ductile iron body (ASTM A 536 Grade 4) for corrosion resistance and longevity. Internal components include NORYL™ seat rings and check valves, stainless steel stems, and EPDM seat disc elastomers. * Versatile Installation (475/475V): Model 475 supports vertical flow up and vertical flow down ("N" pattern), while Model 475V is specifically for vertical upward flow ("Z" pattern), offering flexibility for various space requirements and retrofit installations. * Low Headloss Wilkins Compound Check: Patented design for superior hydraulic performance and reliability, minimizing pressure drop across the device. * Easy Maintenance: Designed with a single access cover and accessible check valves for simplified servicing without removing the entire device from the line. * Approvals and Compliance: ASSE Listed 1013, AWWA Compliant C511 and C550, CSA Certified, IAPMO Listed, UL Classified, C-UL Classified, FM Approved, NSF/ANSI/CAN 61 certified (lead-free compliant). * High Working Pressure and Temperature: Maximum working water pressure of 175 PSI and temperature of 140°F (350 PSI hydrostatic test pressure). Benefits: * Superior Water Supply Protection: Safeguards potable water from contamination (chemicals, stagnant water) that can be present in fire sprinkler systems, meeting public health requirements. * Ensures Fire System Readiness and Compliance: Provides a reliable and inspectable component vital for the proper functioning and regulatory compliance of fire protection systems. * Reduces Downtime and Maintenance Costs: Easy access for inspection and repair streamlines maintenance procedures. * Long-Term Reliability: Robust construction and quality materials ensure extended service life and consistent performance in demanding fire protection environments. * Flexible Application: Accommodates diverse installation needs, including compact spaces and vertical flow configurations. SEO Considerations: * Keywords: "Fire Protection Backflow Preventer," "WILKINS 475/475V," "OSY," "Reduced Pressure Principle," "RP backflow," "potable water protection," "fire sprinkler system compliance," "backflow prevention assembly," "ASSE 1013," "NFPA 13/25 compliance" (clarify that it enables compliance with local AHJ requirements, not directly required by NFPA for fire purposes, but for health). * Search Intent: Users are looking for a reliable, compliant backflow preventer for fire systems, often concerned with public health, system integrity, and ease of maintenance. * Differentiation: Highlight the RP principle for high-hazard protection, the OSY clear indication, robust materials, and Wilkins' reputation for low headloss and easy maintenance. * Authentic Voice: Use clear, professional language. I will structure the description following the requested HTML format and integrate these points. I will also make sure to use "Reduced Pressure Principle" correctly, as it's a key differentiator from Double Check.

Wilkins 475/475V OSY Reduced Pressure Backflow Preventer: Essential Potable Water Protection for Fire Systems

The WILKINS 475/475V OSY Reduced Pressure Principle (RP) Backflow Preventer is a critical component for safeguarding potable water supplies from potential contamination within fire protection systems. Engineered for reliability and compliance, this assembly ensures the integrity of public water mains while supporting the operational readiness of your fire sprinkler system. Ideal for building owners, facility managers, and fire protection professionals, it addresses the vital need for robust cross-connection control where health hazards exist.

  • Reduced Pressure Principle (RP) Design: Offers the highest level of protection against both backpressure and backsiphonage, making it suitable for high-hazard applications where non-potable fire system water could contaminate the drinking water supply.
  • Outside Stem and Yoke (OS&Y) Gate Valves: Features OS&Y shut-off valves that provide a clear visual indication of the valve's open or closed status. This external stem movement is essential for quick, reliable inspection and ensures system readiness in fire protection scenarios.
  • Durable Construction Materials: Constructed with an epoxy-coated ductile iron body (ASTM A 536 Grade 4) for exceptional corrosion resistance and longevity. Internal components, including NORYL™ seat rings and check valves, stainless steel stems, and EPDM elastomers, are selected for superior performance and durability.
  • Versatile Installation Options: The Model 475 offers an "N" pattern for vertical flow up and vertical flow down applications, while the Model 475V features a "Z" pattern specifically designed for vertical upward flow, providing flexibility for new installations and retrofits in diverse spaces.
  • Patented Compound Check: Equipped with Wilkins' patented, center-stem guided Compound Check, designed for exceptionally low headloss and superior hydraulic performance, minimizing pressure drop across the assembly.
  • Simplified Maintenance: Engineered with a single access cover and easily accessible check valves, facilitating streamlined inspection, testing, and servicing without needing to remove the entire device from the pipeline.
  • Industry-Leading Certifications: Fully compliant with rigorous standards including ASSE Listed 1013, AWWA C511 and C550, CSA Certified, IAPMO Listed, UL and C-UL Classified, FM Approved, and NSF/ANSI/CAN 61 Annex G for lead-free compliance.
  • Robust Operating Parameters: Designed to handle a maximum working water pressure of 175 PSI and a maximum working temperature of 140°F, with a hydrostatic test pressure of 350 PSI, ensuring reliable performance under demanding conditions.

Investing in the WILKINS 475/475V OSY Reduced Pressure Backflow Preventer delivers comprehensive protection for your potable water system. It provides peace of mind by preventing the backflow of potentially contaminated water from fire sprinkler systems into the public supply, a crucial requirement often mandated by local plumbing codes and water authorities to protect public health. Its robust design, clear operational status indication, and ease of maintenance ensure long-term reliability and compliance with regulatory requirements, safeguarding both your property and community water resources.

Shipping Information

For Shiping Information visit here

Ver todos los detalles

Top Brands We Stock

Get Yours In 3 Simple Steps

Step 1

Add to cart

Add the air compressor to your cart and choose a payment plan that suits you

Step 2

Choose delivery or pickup

Select home delivery on your ideal date or pick up from your nearest store

Step 3

Stay fire-ready

Enjoy reliable, NFPA-compliant performance 24/7

Product Details

The Wilkins 475/475V OSY is a Reduced Pressure Principle (RP) backflow preventer, not a Double Check Detector Assembly (DCDA). The initial product title mentioned "DCDA" which seems incorrect based on the search results. I will correct this in the description.
The OSY refers to "Outside Stem and Yoke" gate valves, which provide a clear visual indication of whether the valve is open or clo...

Certified By Trusted Trade Associations

Frequently Asked Questions

The Fire Protection Parts Difference: Your Specialized Partner for Critical Components. Call us (800) 976-2489.

At Fire Protection Parts, we understand that maintaining effective fire suppression systems requires readily available, high-quality components. We are not a general supplier; our exclusive focus is on fire protection parts, which allows us to offer unparalleled expertise and a comprehensive inventory in this vital niche.

Why Choose Fire Protection Parts?
Unwavering Product Specialization: Our deep focus on fire sprinkler system components, and specific types of suppression system valves ensures our knowledge and resources are entirely dedicated to your systems' intricate needs.

Exceptional Customer Experience: Customers consistently praise our great communication, excellent service, and helpful support. We prioritize clear and timely interactions to meet your needs efficiently.

Streamlined Online Platform: Our website, Fireparts.com, is well-organized and easy-to-navigate, simplifying procurement. Find the exact parts you need quickly with detailed information and an efficient ordering process.

Reliability and Speed: Timely delivery is critical. We are committed to prompt and reliable shipping, ensuring you receive necessary parts quickly for scheduled maintenance or urgent repairs.

Dedicated Technical Support: Our team offers knowledgeable technical support to assist with part identification, troubleshooting, and informed decision-making.

Choose Fire Protection Parts as your partner. We deliver specialized products with exceptional service, technical expertise, and reliable speed, dedicated to being your trusted source for all your fire protection needs.

Ordering and Shipping Information

We strive to make your ordering process seamless and ensure your critical fire protection components are delivered promptly.

How to order

Order efficiently via our user-friendly website, Fireparts.com. Simply add products to your cart and proceed to our secure checkout. Our knowledgeable support team is available if you need assistance.

Shipping & Transit
Carriers: We primarily use reliable carriers like UPS and FedEx. For larger, heavier items, we utilize LTL freight carriers (e.g., FedEx Freight, R & L).

Origin & Handling: Most orders ship from our manufacturer's warehouse in Chicago, IL or warehouse near you. Orders are typically processed within 1-2 business days (M-F), with a 3:00 PM CST cut-off.

Transit Times (US): Standard transit is generally 2-3 business days to all US destinations, resulting in an estimated total delivery time of 2-4 business days from placement.

Free Shipping: We offer free standard ground shipping on orders in stock totaling $1,100.00 or more within the contiguous United States via FedEx Ground.

Expedited Options: Next-day and two-day air services are available for urgent needs. Contact us for quotes and availability.

International: We ship to the US, Canada, Mexico, and most international destinations. Allow 3-5+ additional business days for processing. Customers are responsible for all duties and taxes.

HAZMAT: Certain items (CPVC, fire extinguishers, etc.) cannot ship via USPS or air and may incur special fees.

Important Note for Freight (LTL)
Thoroughly inspect all LTL shipments for damage before accepting delivery. If damage is present, refuse the delivery and contact us immediately to arrange a replacement.

Once shipped, you will receive an email with a tracking number. All shipping times are estimates provided by the carriers and are not guaranteed.

Our Return Policy

Effective: April 30, 2025

Your satisfaction is important to Fire Protection Parts. Please review our policy for returns.

General Returns
We accept returns of most new, unused, and resalable items in original packaging within 30 days of receipt. A valid proof of purchase is required.

Initiation: Contact us at info@fireprotectionparts.net to start a return and obtain a Return Merchandise Authorization (RMA) number.

Shipping: The customer is responsible for all return shipping costs to: Fire Protection Parts Returns, 2135 City Gate Ln #3018, Naperville, IL, 60563.

Restocking Fee: A 25% restocking fee will be applied to all eligible returns.

Return and Refund Process
Request RMA: Email info@fireprotectionparts.net.

Package Securely: Include the RMA number clearly inside the package.

Refunds: Once inspected, refunds (less the 25% restocking fee and original shipping) will be credited to your original payment method within 14 business days.

Exceptions
Defective/Damaged Items: Contact us immediately upon receipt for instructions.

Exchanges: Place a new, separate order for the desired item and return the original for a refund (subject to terms).

Special Order Items: These are non-returnable and non-refundable unless the manufacturer accepts the return.

All products are subject to the manufacturer's warranty, not direct warranties from Fire Protection Parts. All sales are governed by our Standard Terms and Conditions of Sale.

Any material or equipment that is made to order or custom is non-returnable and non-refundable.

Installation Assistance

Installation Assistance

While Fire Protection Parts specializes in providing high-quality fire protection components, we understand that proper installation is crucial for the effectiveness and safety of these systems.

For professional installation services across the United States, we recommend our trusted partner: Fire & Life Safety Consultants.

As a nationwide fire protection contractor, Fire & Life Safety Consultants offers comprehensive installation services for a wide range of fire protection systems.

To inquire about installation services, please:

Visit their website: www.fireandlifesafety.net to learn more about their services and coverage or call (800) 976-2489.

Email job information: Send the details of your installation needs to info@fireprotectionparts.net, and we will forward your inquiry to the team at Fire & Life Safety Consultants.

Please note that while we facilitate this connection, all installation services and agreements will be directly between you and Fire & Life Safety Consultants.

Technical Support

At Fire Protection Parts, we're committed to providing you with the expertise you need. If you require technical assistance with product selection, troubleshooting, or any other inquiries, our knowledgeable support team is ready to help.

Please call our experts directly at (800) 976-2489 for immediate assistance.

Still got questions?

Our friendly staff are here to help.
Start a chat, give us a call or visit us in store!