Technical Specifications (Material Focus)
The Deringer 40 Reduced Pressure Zone Assembly (RPZA) features a rugged main body constructed from fusion-bonded epoxy-coated ductile iron conforming to ASTM A536 standards. This design ensures high mechanical strength and corrosion resistance suitable for both subterranean and exposed installations. Internally, the assembly utilizes 300-series stainless steel springs and fasteners to prevent corrosion and maintain consistent valve performance. The check valve modules incorporate glass-filled Noryl™ or an equivalent thermoplastic known for durability and chemical resistance. EPDM elastomer discs serve as the seats, offering reversible and field-replaceable sealing surfaces to secure a tight shut-off that prevents backflow contamination.

Regulatory Compliance
This RPZA meets rigorous industry standards required for fire protection and potable water safety:

  • UL Listed: Certified to UL 1613 for Reduced Pressure Principle Backflow Preventers
  • FM Approved: Factory Mutual tested and approved specifically for fire protection applications
  • ASSE 1013: Conforms to American Society of Sanitary Engineering standards governing reduced pressure backflow prevention devices
  • AWWA C511: Compliant with American Water Works Association standards ensuring reliability in water supply systems
Additionally, it supports compliance with NFPA 13 for sprinkler system installations and NFPA 25 for inspection, testing, and maintenance protocols, incorporating pre-drilled test cocks for straightforward annual verification and differential pressure assessment.

Operational Compatibility
Designed to withstand working pressures up to 175 PSI (12.1 bar), the Deringer 40 RPZA operates reliably within a temperature range of 33°F to 140°F (0.5°C to 60°C). Connection options include flanged ANSI B16.1 and grooved AWWA C606 ends, allowing integration with widely used piping systems in fire suppression and municipal water infrastructure. The assembly supports installation in both horizontal and vertical flow orientations, optimizing flexibility across diverse piping layouts.

The Deringer 40 Reduced Pressure Zone Assembly is engineered to prevent hazardous backflow in non-health hazard environments such as fire protection systems. It is suitable for commercial, industrial, and institutional facilities requiring dependable contamination control and compliance with stringent safety codes. Its robust construction mitigates maintenance frequency and downtime, addressing common concerns in high-demand fire protection settings where water purity and system integrity are critical.

Compared to simpler check valve assemblies, the Deringer 40 includes a differential relief valve that actively discharges any backpressure or back-siphonage, effectively preventing pollutant entry into the potable water supply. This feature is essential for fire line applications where pressure fluctuations are frequent and can compromise less sophisticated devices. Its durable materials and tested design reduce the risk of corrosion-related failures, a common issue in wet or underground installations.

Practical insights for system designers and maintenance personnel: the reversible EPDM seats facilitate cost-effective field servicing without full assembly replacement, and the integration of standard test ports simplifies compliance testing per local fire codes. When installed according to manufacturer guidelines, the Deringer 40 RPZA contributes directly to sustained NFPA compliance and potable water safety in fire sprinkler networks.

Shipping Information

For Shiping Information visit here

Afficher tous les détails

Top Brands We Stock

Get Yours In 3 Simple Steps

Step 1

Add to cart

Add the air compressor to your cart and choose a payment plan that suits you

Step 2

Choose delivery or pickup

Select home delivery on your ideal date or pick up from your nearest store

Step 3

Stay fire-ready

Enjoy reliable, NFPA-compliant performance 24/7

Product Details


Technical Specifications (Material Focus)
The Deringer 40 Reduced Pressure Zone Assembly (RPZA) features a rugged main body constructed from fusion-bonded epoxy-coated ductile iron conforming to ASTM A536 standards. This design ensures high mechanical strength and corrosion resistance suitable for both subterranean and exposed installations. Internally, the assembly utilizes 300-se...

Certified By Trusted Trade Associations

Frequently Asked Questions

The Fire Protection Parts Difference: Your Specialized Partner for Critical Components. Call us (866) 906-1526.

At Fire Protection Parts, we understand that maintaining effective fire suppression systems requires readily available, high-quality components. We are not a general supplier; our exclusive focus is on fire protection parts, which allows us to offer unparalleled expertise and a comprehensive inventory in this vital niche.

Why Choose Fire Protection Parts?
Unwavering Product Specialization: Our deep focus on fire sprinkler system components, and specific types of suppression system valves ensures our knowledge and resources are entirely dedicated to your systems' intricate needs.

Exceptional Customer Experience: Customers consistently praise our great communication, excellent service, and helpful support. We prioritize clear and timely interactions to meet your needs efficiently.

Streamlined Online Platform: Our website, Fireparts.com, is well-organized and easy-to-navigate, simplifying procurement. Find the exact parts you need quickly with detailed information and an efficient ordering process.

Reliability and Speed: Timely delivery is critical. We are committed to prompt and reliable shipping, ensuring you receive necessary parts quickly for scheduled maintenance or urgent repairs.

Dedicated Technical Support: Our team offers knowledgeable technical support to assist with part identification, troubleshooting, and informed decision-making.

Choose Fire Protection Parts as your partner. We deliver specialized products with exceptional service, technical expertise, and reliable speed, dedicated to being your trusted source for all your fire protection needs.

Ordering and Shipping Information

We strive to make your ordering process seamless and ensure your critical fire protection components are delivered promptly.

How to order

Order efficiently via our user-friendly website, Fireparts.com. Simply add products to your cart and proceed to our secure checkout. Our knowledgeable support team is available if you need assistance.

Shipping & Transit
Carriers: We primarily use reliable carriers like UPS and FedEx. For larger, heavier items, we utilize LTL freight carriers (e.g., FedEx Freight, R & L).

Origin & Handling: Most orders ship from our manufacturer's warehouse in Chicago, IL or warehouse near you. Orders are typically processed within 1-2 business days (M-F), with a 3:00 PM CST cut-off.

Transit Times (US): Standard transit is generally 2-3 business days to all US destinations, resulting in an estimated total delivery time of 2-4 business days from placement.

Free Shipping: We offer free standard ground shipping on orders in stock totaling $1,100.00 or more within the contiguous United States via FedEx Ground.

Expedited Options: Next-day and two-day air services are available for urgent needs. Contact us for quotes and availability.

International: We ship to the US, Canada, Mexico, and most international destinations. Allow 3-5+ additional business days for processing. Customers are responsible for all duties and taxes.

HAZMAT: Certain items (CPVC, fire extinguishers, etc.) cannot ship via USPS or air and may incur special fees.

Important Note for Freight (LTL)
Thoroughly inspect all LTL shipments for damage before accepting delivery. If damage is present, refuse the delivery and contact us immediately to arrange a replacement.

Once shipped, you will receive an email with a tracking number. All shipping times are estimates provided by the carriers and are not guaranteed.

Our Return Policy

Effective: April 30, 2025

Your satisfaction is important to Fire Protection Parts. Please review our policy for returns.

General Returns
We accept returns of most new, unused, and resalable items in original packaging within 30 days of receipt. A valid proof of purchase is required.

Initiation: Contact us at info@fireprotectionparts.net to start a return and obtain a Return Merchandise Authorization (RMA) number.

Shipping: The customer is responsible for all return shipping costs to: Fire Protection Parts Returns, 2135 City Gate Ln #3018, Naperville, IL, 60563.

Restocking Fee: A 25% restocking fee will be applied to all eligible returns.

Return and Refund Process
Request RMA: Email info@fireprotectionparts.net.

Package Securely: Include the RMA number clearly inside the package.

Refunds: Once inspected, refunds (less the 25% restocking fee and original shipping) will be credited to your original payment method within 14 business days.

Exceptions
Defective/Damaged Items: Contact us immediately upon receipt for instructions.

Exchanges: Place a new, separate order for the desired item and return the original for a refund (subject to terms).

Special Order Items: These are non-returnable and non-refundable unless the manufacturer accepts the return.

All products are subject to the manufacturer's warranty, not direct warranties from Fire Protection Parts. All sales are governed by our Standard Terms and Conditions of Sale.

Installation Assistance

Installation Assistance

While Fire Protection Parts specializes in providing high-quality fire protection components, we understand that proper installation is crucial for the effectiveness and safety of these systems.

For professional installation services across the United States, we recommend our trusted partner: Fire & Life Safety Consultants.

As a nationwide fire protection contractor, Fire & Life Safety Consultants offers comprehensive installation services for a wide range of fire protection systems.

To inquire about installation services, please:

Visit their website: www.fireandlifesafety.net to learn more about their services and coverage or call (800) 976-2489.

Email job information: Send the details of your installation needs to info@fireprotectionparts.net, and we will forward your inquiry to the team at Fire & Life Safety Consultants.

Please note that while we facilitate this connection, all installation services and agreements will be directly between you and Fire & Life Safety Consultants.

Technical Support

At Fire Protection Parts, we're committed to providing you with the expertise you need. If you require technical assistance with product selection, troubleshooting, or any other inquiries, our knowledgeable support team is ready to help.

Please call our experts directly at (866) 906-1526 for immediate assistance.

Still got questions?

Our friendly staff are here to help.
Start a chat, give us a call or visit us in store!